CML Valva regulatrix fluxus operata solenoidalis SF_SFG_SDF_THF_SD_SFD_SKF | CE & ISO Approbatum Solutio hydraulica | Fide dignum a ducibus industriae – CML

Valvula Fluxus Control, Valvula Hydraulica, Valvula Relaxationis | 40 annorum experientia, Professionalium pomparum hydraulicarum & Clavium, Asiae Solus Agens Eckerle, Experta turma, Dives productorum genera, Solutio totalis, Flexibilis customizatio, Globalis distributio.

Valvula Fluxus Controlata Solenoide - CML Valva regulatrix fluxus operata solenoidalis SF_SFG_SDF_THF_SD_SFD_SKF
  • Valvula Fluxus Controlata Solenoide - CML Valva regulatrix fluxus operata solenoidalis SF_SFG_SDF_THF_SD_SFD_SKF

Valvula Fluxus Controlata Solenoide

SF-G06,SDF-G06,THF-G06,SD-G06,SFD-G06,SKF-G06

Valvula Fluxus Control, Valvula Hydraulica, Valvula Relaxationis

Est combinatio valvae regulatricis acceleratricis et valvae directionalis electromagneticae, et secundum combinationem numerumque adjustmentis in sex species dividitur, et in plasticis injectionibus et pressis hydraulicis frequenter utitur.

Valva regulatrix velocitatis bini gradus SF, fluxus liquidus in tempore normali liberum est, et velocitas fluxus regi potest cum valva solenoidalis agit. Utiturur cum actuator bini gradus lento/rapido controllo requiritur.

Valva regulatrix velocitatis unius gradus SDF, fluxus liquidus normaliter clausus est, et velocitas fluxus regitur cum valva solenoidalis agit. Utiturur cum actuator cum signis electricis incipit et desinit et controllo velocitatis requiritur.

Valva regulatrix velocitatis trium graduum SKF solenoidalis adhibetur ad controllo lento/rapido/urgentis.

Valva regulatrix velocitatis bini gradus SFD ad controllo lento/rapido velocitatis adhibetur.

Valva commutatrix solenoidalis, fluxus liquidus normaliter clausus est, et fluxus liquidus liber est cum valva solenoidalis agit.

THF sine valva directionali electromagnetica, tantum functio regulandi habet.

Galeriae Media

Applicatio

  • Machinae industriales.
  • Omnis generis machinae hydraulicae specificae.

Specificatio

SF G 06 3 R
Model Installationis genus Port Gubernator externus Externi Exhaurire
Valvula Operata Solenoide Fluxus Control SF G: Placa 06:3/4”
10:1 - 1/4"
E T

Data Technica
Typus Maxima Pressio
  
(bar)
Max. Fluxus
  
(LPM)
Valvula Pilotus Pondus
  
(kg)
SF-G06 210 120 WH42-G02-B2S 6.4
SDF-G06 WH42-G02-B2 6.4
THF-G06 5.0
SD-G06 WH42-G02-B2 6.1
SFD-G06 WH42-G02-B2S 6.7
SKF-G06 WH43-G02-C4 7.5
SF-G10 240 WH42-G02-B2S 9.9
SDF-G10 WH42-G02-B2 9.9
THF-G10 8.4
SD-G10 WH42-G02-B2 9.4
SFD-G10 WH42-G02-B2S 10.4

Exemplar No.

SF-G06, SDF-G06, THF-G06, SD-G06, SFD-G06, SKF-G06, SF-G10, SDF-G10, THF-G10, SD-G10, SFD-G10, SKF-G10

Codex

Model Code
Codex Modelli Valvulae Fluxus Moderatae Solenoide
DWG

Mensura

SF-G06.G10

Valvula Fluxus Moderata a Solenoide SF-G06.G10 (Valvula Conventionalis) mensurae figura

SDF-G06.G10

Valvula Fluxus Moderata a Solenoide SDF-G06.G10 (Valvula Conventionalis) mensurae figura

SD-G06.G10

Valvula Fluxus Moderata a Solenoide SD-G06.G10 (Valvula Conventionalis) mensurae figura

SFD-G06.G10

Valvula Fluxus Moderata Solenoide SFD-G06.G10(Valvula Conventionalis) dimensio pictura

SKF-G06

Valvula Fluxus Moderata Solenoide SKF-G06(Valvula Conventionalis) dimensio pictura

THF-G06.G10

Valvula Fluxus Moderata Solenoide THF-G06.G10(Valvula Conventionalis) dimensio pictura
Notitia

Instructio

Aptatio pressurae: Cum pressuram aptas, nutum claudens laxare et manubrium lente vertere, horologium ad maiorem pressuram, contra horologium ad minorem pressuram, ne obliviscaris nutum firmans post aptationem.

Oleum reditus genus: Tubus olei reditus directi et remoti non debet coniungi cum tubo olei reditus aliarum valvarum, sed directe ad vas olei redire debet. Si capacitas interna lineae reditus nimis magna est, frequens vibratio evenire potest. Itaque longitudo et diametro ductus quam maxime minuendis sunt.

Selectio fluxus: Cum fluxus parvus est, pressio adaequationis instabilis erit. Ergo, cum utitur calibro 03 et 06, fluxus maior esse debet quam 5 L/min, et cum utitur calibro 10, fluxus maior esse debet quam 8 L/min.


De CML

Clicca ut download pro plura de societate

Valvula Fluxus Controlata Solenoide | EMC, ISO 9001, et CE Certificata Valvulae Hydraulicae – CML’s Globalis Recognitio

In Taiwan ab anno 1981 sita, Camel Precision Co., Ltd. est Valvula Fluxus Controlata Solenoide (exemplar: SF-G06,SDF-G06,THF-G06,SD-G06,SFD-G06,SKF-G06) fabricator in industria machinum et apparatum fabricandorum.

In 1981 Camel Precision Co.,Ltd was founded. Administratio societatis plene agnoscit producta altae qualitatis non solum requirere machinas peritissimas, sed etiam scientiam bonam in technologia esse importantem. Company invitavit seniores ingenios ex Germania et Iaponia ad ducendum manufacturam et disciplinam ingeniariam localium in industria hydraulicorum. Offerimus clientibus nostris soleatus industriales, valvulas solenoides directionales potestates, soleatus hydraulicas, soleatus vane, sentinam calces externam, sentinam calces internam, valvulam directionalem, valvulae hydraulicae ... etc.

CML, Camel Hydraulic Oblatum est clientibus summus qualitas Vane Pump, Variabilis Dispositio Vane Pump, Apparatus Internus Pump, Eckerle Asia Agent, Apparatus Externi Pump, Solenoid Valvae, Modular Valvae, Pressurae Valvae reductionis, Fluxus Valvae Imperium, Valvae hydraulicae ab anno 1981, cum provectae technologiae et 38 annorum experientiae, Camel Hydraulic, Camel Precision efficit ut cuiusque emptoris postulata conveniant. .

Facta de societate in numeris

0

Annorum experientia in industria

0

Numerus clientium servitorum

0%

Ratio reemptorum clientium